KitchenAid refrigerator repair, built-ins and ice makers too.
Beaver Appliance repairs KitchenAid refrigerators, built-in and freestanding, plus its wine cellars, beverage centers and ice makers in Tampa Bay and South Florida, as an independent company not affiliated with KitchenAid. A $69 diagnostic visit finds the fault, credited to the repair; the price is in writing before any work.
Call or text and we’ll give you the earliest time we have.
- Diagnostic visit
- $69, credited to the repair
- Price
- In writing, before any work
- Work done
- Only what you approve
- Google rating, South Florida
- 5.0 from 14 reviews


Holding temperature again, in customers’ words
42″ built-in KitchenAid refrigerator
“… fix my 22-year old dying 42" built-in Kitchenaid refrigerator/freezer which I was not ready to replace yet … Both the freezer and the refrigerator sections are holding temperature now, and I'd happily hire him again if I have any more issues. …”
★★★★★ Jennifer S. Jun 2026, Google review Refrigerator
“… The technician took the time to diagnose the problem properly and had everything back up and running. …”
★★★★★ Joey C. Sep 2026, Google review
What is your KitchenAid refrigerator doing?
Something on the display? Go to the alerts and F-codes.
Lit inside, but not cooling
First check: the display, for Demo, Showroom, Shwrm or COOLING OFF. Some KitchenAid refrigerators need cooling turned back on by hand after a power outage or a power surge.
Call us if it still won’t cool with cooling on, or an F starts flashing.
Fridge warm, freezer cold
First check: the vents. Most KitchenAid units make cold air in the freezer and push it to the fresh food side, so keep food off the vents. A door switch that leaves the light on can warm it too, KitchenAid says.
Call us if it stays warm a day after the vents are clear.
Little or no ice
First check: KitchenAid’s cube test. Empty the bin, take no ice for 24 hours, then count: 56 to 72 cubes is normal for a bottom-freezer ice maker, 80 to 120 when the bin isn’t on the door, 100 to 140 when it is.
Call us if the count falls short with the water on and the filter in place.
Frost, or walls sweating inside
First check: the door seal. A sheet of paper shut in the door should hold firmly, KitchenAid says. In humid months some frost and sweating is normal, above all without air conditioning. The manual filed under KitchenAid models, W11509210C (09/21), adds: “Do Not Use Mechanical Devices to Defrost Refrigerator.”
Call us if the frost comes back with the doors sealing.
Water under it, or a leaking filter
First check: turn off the refrigerator’s water supply until it’s fixed. KitchenAid says chemicals and minerals in the water can degrade a filter housing over time until it leaks.
Call us if the housing is cracked, or it still drips with every fitting tight.
Buzzing, clicking or gurgling
First check: the ice maker. Switched on with no water line connected, its valve buzzes or clicks as it tries to fill, KitchenAid says, so turn it off. Gurgling after a cooling cycle is on its list of normal sounds.
Call us if a new noise doesn’t settle down.
KitchenAid refrigerator alerts and F-codes
Photograph the display and the model label before you reset anything.
KitchenAid explains its alerts in plain words; its F-codes it lists with no meaning at all.
| On the display | What KitchenAid says Its step |
|---|---|
| PO Power Outage | The Power Outage indicator lets you know if the power supply to the refrigerator has been off and the freezer temperature has risen to 18°F (-8°C) or higher. French door, side-by-side, built-in: “Confirm” will blink until you acknowledge the power outage by pressing MEASURED FILL under “Confirm.” Bottom freezer: Touch any button to stop the tone and turn off the Power Outage icon. |
| Alarm Over Temperature light | The Over Temperature feature is designed to let you know when either the refrigerator temperature rises above 48°F (9°C) or the freezer temperature rises above 15°F (-9°C) for longer than 1¹⁄₂ hours. French door: the light flashes until the Alarm is pressed. Built-in: To turn off the alarm and indicator light, press the “Over Temperature Reset” button. |
| Door alarm tone | The Door Ajar Alarm feature sounds an alarm when the refrigerator door(s) or freezer drawer is left open for 2-5 minutes, depending on the model, and cooling is turned on. Close all doors to turn off and reset the alarm. |
| Cooling Off | Your refrigerator and freezer will not cool when cooling is turned off. Not a fault KitchenAid’s common method: Press and hold LOCK and MEASURED FILL for 3 seconds again to turn cooling back on. |
| Demo Showroom Shwrm | Demo mode powers the display and lights while disabling cooling. Not a fault KRFF300E: Hold MOISTURE CONTROL and MAX COOL buttons for three seconds. |
| Filter Replace Filter, blinking | The “Replace Filter” icon will illuminate and blink continuously during dispensing when the rated volume of water has passed through the filter or 6 months have passed since the filter was installed. New filter in, then on a bottom freezer: Press and hold the “Freezer” and “Drawer” button for 3 seconds. |
| F flashing, or an F-code | On KitchenAid’s list, with no meaning given. Power unit down by turning off the circuit breaker(s) or unplugging the product for one (1) minute. Power unit up by turning on the circuit breaker(s) or plugging the product back in. Ensure the cooling function is turned on. Monitor the refrigerator for one (1) minute to ensure the error code does not display again. If the problem persists, schedule service. FE E3 starts with the water: Ensure the water supply is turned on and open. Check the water line for kinks. Bottom freezer: F1 E1 F3 E1 F3 E2 F3 E4 F3 E8 F3 E9 F3 EB F4 E1 F4 E8 F4 E9 F4 ED F4 EE F6 E1 F7 E1 F9 E1 F9 E3 F9 E4 FA E1 FA EB FA EC FB E1 FB E2 FB E8 FB E9 FB EA FB EB FB EE FD E1 FD E2 FD E4 FD E5 FE E3 FE E7. French door: F3 E1 F3 E2 F3 E4 F3 E8 F3 E9 F3 EC F4 E1 F6 E1 F8 E1 F8 E2 F8 E3 F8 E8 F8 EC. |
| Call for Service light, built-in | No meaning given on KitchenAid’s built-in pages. Power unit down by turning off the circuit breaker(s) for five (5) minutes. Power unit up by turning on the circuit breaker(s). Monitor the refrigerator for a couple of minutes to ensure the error code does not display again. |
| PF, P0 or 01 | Not on KitchenAid’s own code list. Text us a photo of the display and the model label. |
KitchenAid built-ins: the switch and the waits
KitchenAid’s built-ins (KBSN, KBFN and KBBR models among them) have help pages of their own.
- No power at all
- Remove the top grille panel. Press the Power switch to the ON position. Replace the grille cover.
- Control panel not responding
- Power unit down by turning off the circuit breaker(s) or unplugging the product for 5 - 10 minutes.
- The condenser
- KitchenAid’s built-in side-by-side manual, W11504344G (07/23): “There is no need for routine condenser cleaning in normal home operating environments. If the environment is particularly greasy or dusty or there is significant pet traffic in the home, the condenser should be cleaned every 6 months to ensure maximum efficiency.” “If you are unable to clean the condenser, please call for service.”
Text us the display and the label
French door or bottom freezer: inside the refrigerator compartment, on the left-hand side; side-by-side, the right-hand side. KitchenAid lists no spot for built-ins: check the sides and the inside.
Text a photo to (813) 513-1699A KitchenAid refrigerator visit, step by step
Tell us what it’s doing
Call or text us. The appliance, the symptom and any code are enough to start.
We find the fault
A technician comes to you for the $69 diagnostic visit, credited to the repair if you go ahead.
Get the price in writing
Before any work starts. No repair until you say yes.
We fix it
Only the work you approved, at the price you approved.
Get the paperwork
The appliance, the work done and the date, in writing.

Lost power while you waited? KitchenAid’s rule: “If the refrigerator has been above 40°F for more than 2 hours, perishable items should be discarded.”
KitchenAid refrigerator questions
Not answered here? Call (813) 513-1699 Text us the display
Do you repair KitchenAid wine cellars, beverage centers and undercounter ice makers?
Yes, and KitchenAid’s undercounter refrigerators. KitchenAid’s help pages list E1, E2 and HI or LO messages for them; text us a photo of the display and the label, which on a wine cellar or beverage center sits on the right-hand side, near the top door hinge. A freestanding ice maker has a reset button, KitchenAid says, to press and hold for a few seconds.
How do I reset a KitchenAid refrigerator?
KitchenAid has no single reset. A flashing F gets a minute without power, a built-in’s Call for Service light five minutes at the breaker, and a built-in panel that won’t respond 5 to 10 minutes. Ice that’s made but never drops gets one minute unplugged.
Is my KitchenAid refrigerator still under warranty?
On its help pages, KitchenAid says its limited warranty “typically lasts a year from the date of purchase, but warranty length will depend on the appliance type.” Check the booklet that came with yours. While it’s covered, start with KitchenAid.
Has KitchenAid recalled any refrigerators?
CPSC lists no KitchenAid refrigerator recall (checked November 2026). For a specific model and serial number, ask KitchenAid.
More on KitchenAid and built-ins
Where we work
Beaver Appliance repairs KitchenAid refrigerators across Tampa Bay: Pasco and Hillsborough counties and nearby parts of Pinellas and Hernando counties. Call or text (813) 513-1699.
- Appliance repair in Tampa Bay
- Land O’ Lakes
- Odessa
- Lutz
- Wesley Chapel
- New Port Richey
- Tampa
- Zephyrhills
- Brandon
- Spring Hill
- Palm Harbor
- Clearwater
- Keystone
- Trinity
- Carrollwood
- Westchase
- New Tampa
- South Tampa
Beaver Appliance repairs KitchenAid refrigerators across South Florida: Broward County and nearby parts of Miami-Dade and Palm Beach counties. Call or text (754) 285-8880.